FMC Power Module DS#T0008 REV 2026/11/25 PDF version | HTML version | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| FPGA Mezzanine Card (FMC)Power Module | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Features
|
FMC Power Module
![]()
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Applications
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
1. Description
An FPGA mezzanine card (FMC) draws its power from four rails: 12P0V, 3P3V, VADJ and 3P3VAUX. On a carrier board these rails run straight from the regulators to the FMC connector, so the voltage and the current of a single rail cannot be measured, and a rail cannot be fed from outside. Every mezzanine has to store its power requirements in the EEPROM of its Field Replaceable Unit (FRU), and those figures come from a measurement. The FMC Power Module is plugged in between carrier and mezzanine and opens each of the four rails. It was built for three jobs:
All other FMC HPC signals are passed straight through from the mezzanine card connector P5 (MC-HPC-10, bottom side, faces the carrier) to the carrier card connector P6 (CC-HPC-10, top side, takes the mezzanine). |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 2. Application information
2.1 Rail connectors Each rail is brought to its own 4-pole push-in connector on the board edge, P1 to P4 (tab. 1). The four contacts carry the carrier side of the rail (CC), the mezzanine side (MC), the external input (EXT) and ground (GND). The contacts are named on the silkscreen. Use solid wire or stranded wire with a ferrule, 26 to 20 AWG. Tab. 1: Rail connectors and their contacts.
2.2 Jumpers Twelve 3-pin jumpers set the source of every rail, the reference voltages and the control flags (tab. 2). The middle pin always carries the signal that is being switched; the two outer positions are named on the silkscreen. A HIGH level set with J11 or J12 comes from a 10 kΩ pull-up (R1, R2) to 3P3V on the mezzanine side, so it needs 3P3V there, from the carrier or from the external input. Tab. 2: Jumpers and their positions. Silkscreen names in capitals.
2.3 Measuring voltage and current The voltage of a rail at the mezzanine is measured between the MC and GND contacts of its connector, the voltage delivered by the carrier between the CC and GND contacts. The current a mezzanine draws from the carrier is measured in one of two ways:
With the jumper on EXT, the current is the current of the external supply. A rail whose jumper is removed and that has no ammeter in its place is open: the mezzanine gets no supply on it. 2.4 External supply and stand-alone operation Set the jumper of a rail to EXT and connect a bench supply between the EXT and GND contacts of its connector. The carrier side of that rail then ends at the CC contact and no longer reaches the mezzanine. This is how a mezzanine is run at a voltage the carrier does not deliver, in an overvoltage or undervoltage test for example. Operating a mezzanine outside its specification can damage it. Without a carrier, the FMC Power Module powers a mezzanine stand-alone: set the jumpers of all rails the mezzanine needs to EXT and feed each of them from a bench supply. A mezzanine that waits for PG_C2M gets it with J8 on SET and J12 on HIGH. 2.5 I2C and JTAG The I2C bus (SCL, SDA, GND) and JTAG (TMS, TCK, TDO, TDI, RST for TRST_L, GND) come out on pads next to the mezzanine card connector, named on the silkscreen. SCL and SDA each have a 10 kΩ pull-up (R3, R4) to 3P3V on the mezzanine side. |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 3. Electrical data
The printed circuit board is open-source hardware. The FMC Power Module schematics and the board layout files are on GitHub in their latest revision. Tab. 3: Parts list of the FMC Power Module.
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
4. Mechanical data
The board outline is defined by the ANSI/VITA 57.1 standard for single-width FMC modules and uses the regions 1, 2 and 3. The board measures 84.0 mm × 69.0 mm.
Fig. 1: Mechanical drawing of the FMC Power Module.
The mounting holes are plated but have no electrical connection. Their sizes and positions are in accordance with ANSI/VITA 57.1 single-width FMC modules.
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
5. Ordering information
The FMC Power Module can be ordered at various online market places, or you can request a quotation by sending an e-mail to info@iamelectronic.com.
The board is supplied with twelve jumpers.
Tab. 5: Assembly variants of FMC Power Module with product numbers and market places.
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 6. Document history Document number: DS#T0008 Version history: 2026/11/25: Description rewritten. Added: application information, parts list, current per rail, board dimensions 2022/05/24: Add ordering information, Tindie and ebay article listings 2022/05/20: Initial release | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||