Engineering problem
The FMC voltage rails of a carrier or a mezzanine cannot be measured one by one, and they cannot be fed from outside. Yet every mezzanine has to declare its power requirements in its FRU EEPROM, and those figures come from a measurement.
The problem it solves
An FMC mezzanine draws from four rails: 12P0V, 3P3V, VADJ and 3P3VAUX. On the carrier they are copper between a regulator and the connector, so there is no place to measure the voltage and current of one rail, let alone to take it over from outside.
The FMC Power Module was built for three jobs. The first is measuring. It sits between carrier and mezzanine and opens each of the four rails. Every rail has its own push-in wire connector with the carrier side, the mezzanine side, an external input and ground on separate contacts, so the voltage of a rail is taken at its connector and its current at the connector or in place of its jumper. All other HPC signals pass straight through.
The second is feeding a rail from outside. A jumper per rail decides whether the mezzanine is fed from the carrier or from a bench supply. That is how a mezzanine is run outside its specification, in an overvoltage or undervoltage test for example, at a supply voltage the carrier would never deliver. It is also how a mezzanine is powered stand-alone, with no carrier underneath at all.
The third is setting the FMC control flags by hand. PRSNT can be passed through or tied to ground, and PG_C2M and PG_M2C can each be passed through or set low or high, so a mezzanine can be held in a defined state whatever the carrier does. VIO_B, VREF_A and VREF_B are switchable between the mezzanine and an external source, and I²C and JTAG come out on pads.
The board outline is defined by the ANSI/VITA 57.1 standard for single-width FMC modules. The mounting holes are plated but have no electrical connection.
Features
- HPC pass-through between carrier and mezzanine: all FMC HPC signals are forwarded.
- All four voltage rails (12P0V, 3P3V, VADJ, 3P3VAUX) are opened and brought to a push-in wire connector each.
- Every rail connector carries the carrier side, the mezzanine side, an external input and ground on separate contacts.
- Jumper per rail: feed the mezzanine from the carrier or from the external supply.
- Voltage and current measurement on every rail, at its connector or in place of its jumper.
- Works without a carrier: a mezzanine can be powered stand-alone from external supplies.
- Control flags by jumper: PRSNT, PG_C2M and PG_M2C can be passed through or set.
- VIO_B, VREF_A and VREF_B switchable between the mezzanine and an external source.
- I²C and JTAG on pads.
- Open Hardware.
Applications
- Measurements on the power rails of a carrier or a mezzanine: voltage and current, rail by rail.
- Overvoltage and undervoltage tests: feed a rail from a bench supply at a voltage the carrier does not deliver.
- Stand-alone supply: power a mezzanine from bench supplies with no carrier underneath.
- Current consumption per rail: the figures every mezzanine has to store in its FRU EEPROM.
- Compliance and production tests.
- Prototyping and debugging: bring a mezzanine up on bench supplies, with the control flags held where they need to be.